Page 16 - ingenioren
P. 16

SIGNALLING IN GENERAL








            We offer appropriate solutions that are            Alarm
            customized to the relevant requirements of the     E. g. the evacuation alarm in case of a fire.
            various areas of signaling technology:             Devices of this nature generate an alarm for
                                                               emergency situations and have the highest
            • Indication                                       priority.
            • Warning
            • Alarm                                            The alarm can, e.g. be executed for the following
                                                               events:
            Indication                                         •   A dangerous situation has already occurred
            E. g. operation display of a machine informs the   •   Danger of life and limb
            operator by means of a signaling device. These     •   Acute health risk
            types of devices inform personnel who are nearby.   •   Risk for the environment
            These devices are not used for the indication of   •   Abnormal process status
            dangerous situations.                              •   Exceeds maximum tolerance limits
                                                               Reaction of the user: Immediate reaction is
            The signaling can, e.g. contain the following      necessary
            information:
            •   Status of a machine, process, test procedure
            •   Lack of ingoing material / material supply is
                in danger
            •   Quality defect, good / defective information
            •   Process has ended, standby position
            •   Notification and display of errors
            •   Display of room occupancy

            Warning
            E. g. as a start-up signal for a machine. These
            types of devices warn about situations that could
            occur.
            The warning can, e.g. be executed for the
            following events:
            •   Caution: Critical status, proceed with caution
            •   Ready for handling
            •   Attention is necessary
            •   Dangerous situations can occur when no
                measures are in place
            •   Corrective action is necessary within a
                suitable amount of time
            •   Warning of economic and health damages
            •   Process is outside the normal operating limit
                but within an acceptable error limit
            •   A status change is being executed
            Reaction of the user: Monitor and / or take
            corrective action
   11   12   13   14   15   16   17   18   19   20   21