Page 9 - ingenioren.no
P. 9

Air Purge Designs


           By changing the seal environment, even the most challenging applications can
           be reliably sealed.

           •  Dramatically improve the equipment life in
             demanding applications
           •  Prevent contamination across the seal
           •  Maximize reliability with no heat generation, vibration or lubrication













                                                                           Multiple LabTecta ® 66PB-OAP installed on a conveyor belt in the
            LabTecta ® 66TE-OAP installed on a hydropulper gearbox in a pulp mill (Case Ref: 3327)  mining industry (Case Ref: 3317)





                                                    66OAP                                 66IAP


                                                  Airflow
                                                                                        Airflow











                                        LabTecta 66OAP (Outboard Air Purge)    LabTecta 66IAP (Inboard Air Purge)
                                              ®
                                                                                     ®







           The LabTecta 66OAP is specifically designed for
                      ®
           use in extreme environments and applications where
           contamination may completely cover the
           seal / equipment. The unique design uses a positive
           air purge to enhance the performance of the labyrinth,
           with AESSEAL mechanical seal pressure balancing
                      ®
           technology to maximize the performance of the seal
           and minimize air consumption.
                                                       LabTecta ® 66OAP installed on
                                                            a powder application
                                                         (pre-start up) in Argentina
                                                              (Case Ref: 3220)


                                                                         LabTecta ® 66OAP after three months running. Note: Air purge keeps
                                                                                     the dust away from the stator to rotor interface