LabTecta 66 — Save Your Bearings
                         ®

           Research* shows that 52% of bearing failures are due to contamination of the
           bearing oil. These represent 20.8% of all rotating equipment failures. Save your
           bearings and improve your reliability with LabTecta 66.
                                                                         ®


           Research into Bearing Failures                                Cause Categories Equipment Failure

           Reliability by numbers: 52% of bearing failures. A study into equipment
           reliability conducted at a major refinery has published statistics on causes of
           equipment failure. They concluded that 40% of overall rotating equipment failures
           (pumps, mixers, etc) were due to bearing failure.

           They further estimated that 48% of all bearing failures were due to particle
           contamination and a further 4% were due to corrosion (caused by liquid in the
           oil). Therefore 52% (total contamination cause) of 40% (bearing failures)
           = 20.8% of all rotating equipment failures are caused by contamination of
           the bearing oil.




                                   LabTecta 66 has achieved...
                                           ®
                                   Ingress Protection code rating
                                                                                                         66
                                   The premier third-party standard for Ingress Protection.
                                                                                                IP66
                                   Level 6 Protection against solids


                                   Defined as “No ingress of dust; complete protection against contact.”
                                   Level 6 Protection against water


                                   Defined as “Water projected in powerful jets (0.5” / 12.5mm nozzle) against the enclosure from all
                                   practicable angles shall have no harmful effects”. Tested with at least 26 US gallons (100 litres)
                                   per minute for at least 3 minutes, while equipment is both static & rotating.









           Bearing-oil Contamination is Preventable                            Causes of Bearing Failure
           LabTecta 66 is a labyrinth design bearing-protector seal with an innovative
                  ®
           design improvement, the LabTecta 66 shut-off valve, which we believe to
                                      ®
           be the secret to the product’s phenomenal success.
           The effectiveness of LabTecta 66 has been verified in third-party tests
                                  ®
           by the Ingress Protection Code. LabTecta 66 has achieved a rating
                                            ®
           of IP66: proving its effectiveness in protecting your bearings from
           contamination failures.









           * Bloch, Heinz; “Pump Users Handbook: Life Extension” 2011.